MAGNETECH CORPORATION 

Tel: 1-248-426-8840, Fax: 1-248-888-9537, Email: sales@magnetechcorp.com


DC OPPOSITE POLE ELECTROMAGNETS

Price List

Distinct pole on each end.

Max field strength at surface.

Repelling application.

Pole polarity changeable.

Tech Data of Opposite Pole Electromagnets: 

Part Number

Outer
Diameter

Height

Mounting Thread

Thread Depth

Lead Location

Pole Diameter

Lead Length

Net Weight

 

A

B

C

D

E

F

 

 

OP-1212

1-1/4”

1-1/4”

1/4-20

1/2”

3/16”

5/8”

24”

5.7 oz.

OP-2025

2”

2-1/2"

1/4-20

3/4”

1/2”

1”

36”

2 lb.

OP-3030

3”

3”

5/16-18

1”

5/8”

1-1/2”

36”

5 lb.

Application Data of OP-1212 Electromagnet:

Applied Voltage

Current Draw

Average Flux Density
(at surface)

Holding Value
(at no gap)

Repelling Each Other
(at 1/32" gap)

OP-1212

Amps

Gausses

Lbs.

Lbs.

6 V.DC, 100% Duty Cycle

0.72

250

1

0

12 V.DC, 25% Duty Cycle

1.5

450

4

0

18 V.DC, 10% Duty Cycle

2.2

750

8

0.2

24 V.DC, 5% Duty Cycle

2.9

1050

12

0.6

Application Data of OP-2025 Electromagnet:

Applied Voltage

Current Draw

Average Flux Density
(at surface)

Holding Value
(at no gap)

Repelling Each Other
(at 1/32" gap)

OP-2025

Amps

Gausses

Lbs.

Lbs.

6 V.DC, 100% Duty Cycle

1.9

450

12

0

12 V.DC, 25% Duty Cycle

3.7

950

48

0

18 V.DC, 10% Duty Cycle

5.6

1450

84

1

24 V.DC, 5% Duty Cycle

7.5

1950

104

2.5

Application Data of OP-3030 Electromagnet:

Applied Voltage

Current Draw

Average Flux Density
(at surface)

Holding Value
(at no gap)

Repelling Each Other
(at 1/32" gap)

OP-3030

Amps

Gausses

Lbs.

Lbs.

6 V.DC, 100% Duty Cycle

4.3

550

50

0

12 V.DC, 25% Duty Cycle

8.6

1100

150

1

18 V.DC, 10% Duty Cycle

13

1700

250

3

24 V.DC, 5% Duty Cycle

17

2100

300

6


Electromagnets repelling permanent magnets:
There is no test data available, due to too many variables on permanent magnets. For how-to-select permanent magnets see guideline at Application Notes.

 

Safety Caution:

The holding values as listed are actual readings of breaking away a 1/2" steel plate with no air-gaps between them. They have not been de-rated. For safety in holding applications, do not use electromagnets at more than 1/2 of rated value. In lifting applications, do not use at more than 1/4 of rated value. Do not use electromagnets over people.

 
[Home] [News] [Products] [Services] [Applications] [Contact Us] [Price List][Return Policy]

Copyright © 2010 Magnetech Corporation, 22809 Heslip Dr. Novi, Michigan 48375 USA

Tel: 1-248-426-8840     Fax: 1-248-888-9537    E-mail: sales@magnetechcorp.com